1.Size 1.1 Rectifier Length(L) [mm] 270± 2 1.2 Rectifier Width(W) [mm] 100± 2 1.3 Rectifier Heigth(H) [mm] 60± 2 2.Data of Ballast 2.1 Starting voltage min. [V] 180 Vac 2.2 Starting time [S] 5Max 2.3 Pulse voltage [KV] 3-4.5kv 3.Lamp electrical parameter 3.1 Lamp type MH/HPS600W 3.2 Lamp voltage [V] 120(HPS) 3.3 Lamp current [A] 5 3.4 Lamp wattage [W] 600 4. Input parameter 4.1 Input voltage [ V] 230 Vac 4.2 Current reference [A] 3(super) 4.3 Input wattage [W] 680((super) 4.4 Input frequency [HZ] 50/60 4.5 Power factor [ cos
Φ] ≥0.98 4.6 THD / ≤10 5.Output parameter 5.1 Output frequency [kHz] 70-210 5.2 The dimming range 4(250,400,600,super) 5.3 Open circuit voltage [V] ≤400 5.4 Crest factor ≤1.7 5.5 Factor ≥94.5% 6. Other 6.1 Surface temperature [℃] 70Max. 6.2 Ambient temperature [C°] -20-30
WARNING a. Ensure the power shut down before check, install or replace the bulb.